{
    "id": 102,
    "date": "2023-04-04T23:19:10",
    "date_gmt": "2023-04-04T21:19:10",
    "guid": {
        "rendered": "https:\/\/chemimpex.net\/?p=102"
    },
    "modified": "2023-04-15T20:52:48",
    "modified_gmt": "2023-04-15T18:52:48",
    "slug": "amberlite-irn78-oh",
    "status": "publish",
    "type": "post",
    "link": "https:\/\/chemimpex.net\/en\/amberlite-irn78-oh\/",
    "title": {
        "rendered": "AmberLite\u2122 IRN78 OH"
    },
    "content": {
        "rendered": "<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"font-size:18px;flex-basis:66.66%\">\n<h2 class=\"wp-block-heading\">Description<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">AmberLite\u2122&nbsp;IRN78 OH Ion Exchange Resin is designed specifically for use in nuclear loops where highest resin purity and stability are required, and where the &#8220;as supplied&#8221; resin must have a minimum of ionic and non-ionic contamination. These high standards of resin purity enable plants to achieve reliable and safe production whilst reducing the need for equipment maintenance and minimizing the impact of unscheduled outages. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AMBERLITE IRN78 OH is recognized as the premier anion resin in nuclear power applications due to its exceptional total exchange capacity and purity. It contains a minimum of 95% of the exchange sites in the hydroxide form and a maximum of 0.05% in the chloride form, and is further processed to minimize total chloride content to help prevent transient chloride levels when new resin is placed into service in both BWR and PWR systems. The very high total anion exchange capacity can produce a 10 \u2013 15% increase in operating throughput in the intended applications. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Since the nuclear-grade resins from these applications are generally disposed of as rad waste, high capacity and long resin bed life are critical to minimizing rad waste disposal cost and volume. For most users, rad waste disposal cost will often exceed resin purchase cost, so high resin capacity directly translates into savings in these non-regenerable nuclear applications. Furthermore, longer bed life means fewer bed change-outs, less work, less resin handling, and less chance for radiation exposure. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The uniform particle size and the absence of fine resin beads result in a lower pressure drop compared to conventional resins. The particle size of AMBERLITE IRN78 OH is specifically designed to give an optimized balance of pressure drop, exchange kinetics, and resistance to separation from the cation exchange resins, AMBERLITE\u2122 IRN99 H Ion Exchange Resin and AMBERLITE\u2122 IRN97 H Ion Exchange Resin, when used in a mixed bed.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"font-size:16px;flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"259\" height=\"194\" src=\"https:\/\/chemimpex.net\/wp-content\/uploads\/2023\/04\/anion_3.jpg\" alt=\"\" class=\"wp-image-414\" srcset=\"https:\/\/chemimpex.net\/wp-content\/uploads\/2023\/04\/anion_3.jpg 259w, https:\/\/chemimpex.net\/wp-content\/uploads\/2023\/04\/anion_3-16x12.jpg 16w\" sizes=\"auto, (max-width: 259px) 100vw, 259px\" \/><\/figure>\n<\/div>\n\n\n<h4 class=\"wp-block-heading\">Uses<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Primary water treatment: primary coolant purification, treatment of primary coolant blowdown, control of reactor coolant chemistry by removing boron<\/li>\n\n\n\n<li>Fuel pool purification in single bed VVER systems<\/li>\n\n\n\n<li>Rad waste treatment and decontamination: removal of anionic radioactive materials<\/li>\n\n\n\n<li>PWR steam generation blowdown (APG)<\/li>\n\n\n\n<li>BWR condensate polishing<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Advantages<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Nuclear-grade resin with minimum of ionic and non-ionic contamination<\/li>\n\n\n\n<li>Premier anion resin in nuclear power applications due to its exceptional total exchange capacity and purity<\/li>\n\n\n\n<li>Very clean, with extremely low residuals of chloride and other contaminants<\/li>\n\n\n\n<li>Uniform particle size<\/li>\n\n\n\n<li>Highly regenerated ready for use<\/li>\n\n\n\n<li>Low residuals of all metallic species<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-font-size\" style=\"font-size:18px\"><a class=\"wp-block-button__link has-black-color has-very-light-gray-to-cyan-bluish-gray-gradient-background has-text-color has-background wp-element-button\" href=\"https:\/\/chemimpex.net\/wp-content\/uploads\/2023\/04\/IER-AmberLite-IRN78-OH-PDS-45-D01206-en.pdf\" style=\"border-radius:12px\">Product Data Sheet<\/a><\/div>\n<\/div>",
        "protected": false
    },
    "excerpt": {
        "rendered": "<p>AmberLite\u2122\u00a0IRN78 OH Ion Exchange Resin is designed specifically for use in nuclear loops where highest resin purity and stability are required, and where the &#8220;as supplied&#8221; resin must have a minimum of ionic and non-ionic contamination.<\/p>",
        "protected": false
    },
    "author": 1,
    "featured_media": 0,
    "comment_status": "closed",
    "ping_status": "closed",
    "sticky": false,
    "template": "",
    "format": "standard",
    "meta": {
        "footnotes": ""
    },
    "categories": [
        13
    ],
    "tags": [],
    "class_list": [
        "post-102",
        "post",
        "type-post",
        "status-publish",
        "format-standard",
        "hentry",
        "category-anionites"
    ],
    "aioseo_notices": [],
    "_links": {
        "self": [
            {
                "href": "https:\/\/chemimpex.net\/en\/wp-json\/wp\/v2\/posts\/102",
                "targetHints": {
                    "allow": [
                        "GET"
                    ]
                }
            }
        ],
        "collection": [
            {
                "href": "https:\/\/chemimpex.net\/en\/wp-json\/wp\/v2\/posts"
            }
        ],
        "about": [
            {
                "href": "https:\/\/chemimpex.net\/en\/wp-json\/wp\/v2\/types\/post"
            }
        ],
        "author": [
            {
                "embeddable": true,
                "href": "https:\/\/chemimpex.net\/en\/wp-json\/wp\/v2\/users\/1"
            }
        ],
        "replies": [
            {
                "embeddable": true,
                "href": "https:\/\/chemimpex.net\/en\/wp-json\/wp\/v2\/comments?post=102"
            }
        ],
        "version-history": [
            {
                "count": 7,
                "href": "https:\/\/chemimpex.net\/en\/wp-json\/wp\/v2\/posts\/102\/revisions"
            }
        ],
        "predecessor-version": [
            {
                "id": 415,
                "href": "https:\/\/chemimpex.net\/en\/wp-json\/wp\/v2\/posts\/102\/revisions\/415"
            }
        ],
        "wp:attachment": [
            {
                "href": "https:\/\/chemimpex.net\/en\/wp-json\/wp\/v2\/media?parent=102"
            }
        ],
        "wp:term": [
            {
                "taxonomy": "category",
                "embeddable": true,
                "href": "https:\/\/chemimpex.net\/en\/wp-json\/wp\/v2\/categories?post=102"
            },
            {
                "taxonomy": "post_tag",
                "embeddable": true,
                "href": "https:\/\/chemimpex.net\/en\/wp-json\/wp\/v2\/tags?post=102"
            }
        ],
        "curies": [
            {
                "name": "wp",
                "href": "https:\/\/api.w.org\/{rel}",
                "templated": true
            }
        ]
    }
}